AC Fan Control System - Automatic or Manual
AC Fan Control System - Automatic or Manual

AC Fan Control System - Automatic or Manual

For Automatic control of Engine Room Temperature

Availability: Make a selection

Sku# Make a selection
Item ID Make a selection
Mfg# Make a selection
loading image
Checking for Price and Availability
The P/T4 and T4 Series Ventilation Control Systems are state-of-the-art digital ventilation control systems that are designed and manufactured by Delta T Systems specifically for the rigors of the marine engine room.
The P/T version monitors both air pressure and temperature, while the T version monitors only engine room temperature.

With thousands of these systems in use, over the years Delta T has been able to incorporate customer requests for features and modifications into the design of this fourth generation of the P/T4 and T4 producing the most reliable and robust offshore fan control system of its type in the world.

The P/T4 and the T4 each may be run in automatic or manual mode.
Normal operation for these systems is in automatic mode which is activated as soon as the vessel’s engines are started. In Automatic mode, engine room temperature and combustion air intake are automatically controlled to optimum levels based on temperature and pressure for the P/T4, and by engine room temperature alone for the T4.

These systems includes a color touch screen Fan Control Interface (FCI) with the ability to attach up to ten (10) remote displays. Also included is an integrated alarm output that can be connected to a vessel's central alarm system.
Help screens and simplified parameter and monitoring screens make operation and adjustment fast and easy. &&&&&&&&&&&&&&&&&&&&& The P/T4 and T4 Series Systems allows the variable speed control of two or more three-phase fans via a digital touch screen Fan Control Interface (FCI). Each system may be configured to accept single or three phase AC input power to the ASDs (Adjustable Speed Drives), depending on the available power aboard the vessel. The ASDs allow the fan motors to be speed controlled with full reversing capability and virtually eliminates the high starting loads associated with typical single-phase fan installations. Auto Mode: Both the P/T4 and the T4 systems start in Auto Mode when the engines are started. When the P/T4 system switches to Auto Mode, the exhaust fan(s) speed is adjusted automatically as the temperature increases, measured by a sensor located within the engine room. The intake fan(s) speed is controlled by an engine room pressure sensor. This sensor requires a sensing tube to the outside atmosphere as well as to the engine room space to measure the differential pressure. As the engines demand greater volumes of air and the exhaust fan(s) flow increases as temperature rises, the intake fan(s) speed will increase to supply the required airflow, thus maintaining the correct pressure and volume under any conditions. In Auto Mode, the T4 system regulates both the intake and exhaust fans based on engine room temperature alone. Quiet Run: Upon main engine shut down, both the P/T4 and the T4 ventilation control systems switch to the Quiet Run Mode which cools the engine room down at a user specified fixed fan speed. Once a user specified temperature has been reached, the fans will stop thermostatically. Manual Mode: In addition to the two automatic modes of operation there is a Manual Mode. The Manual Mode allows the operator to control the fan speed and direction independently for maintenance or unusual situations. This mode of operation is not recommended for use when underway and the main engines are running.